A firmware upgrade for ScopeMeter test tool 190 Series is available, which gives you the following additional functions:
- Automatic rise and fall time measurement
- Advanced waveform mathematics for adding, subtracting and multiplying waveforms
- A versus B waveform display for advanced signal analysis
Upgrading Version 3.x to Version 4.08 - Instruments with version 3.0 or later are field upgradable free of charge. Click here to download the FlashTool software (634 KB) that allows you to upgrade the instrument firmware. Click here to download a manual supplement with additional information on the new functions.
FlashTool Software requirements:
- Fluke 190 Series ScopeMeter, with software V3.0 or higher. (See Firmware Level Check below);
- A PC, running Windows 95, 98, Me, 2000, NT 4.0 or XP, with a free RS-232 port (COM1 or COM2) to perform the software installation;
- PM9080 optically isolated serial interface cable (as included with the ScopeMeter 190S and 190M models and with the SCC-190 kit) for data interconnection between the PC's RS-232 port and the instrument.
Upgrading earlier Versions - Instruments with firmware prior to version 3.0 cannot be upgraded in the field. These instruments require hardware modification and re-calibration after upgrading. Therefore these units must be returned to a Fluke Authorized Service Center. Contact your local service center and order a hardware upgrade and calibration according to PCN4656 (US part number 1581559) and a firmware upgrade to Version 4 according to PCN4728. Note: For the hardware modification and calibration a nominal fee will be charged!
Firmware Level Check - Press USER and F3 [VERSION & CAL …] on your ScopeMeter to check its firmware version.
ScopeMeter® 190C Series Version 5 Firmware Upgrade
A firmware upgrade for ScopeMeter test tool 190C Series is available, major changes are:
- Improved TrendPlot scaling
- Improved Voltage Readings stability
Upgrading Version 5.01 to Version 5.02 - Instruments with version 5.01 are field upgradable free of charge. Click here to download the FlashTool software (750 KB) that allows you to upgrade the instrument firmware.
FlashTool Software requirements:
- Fluke 190C Series Color ScopeMeter, with software V5.01. (See Firmware Level Check below);
- A PC, running Windows 95, 98, Me, 2000, NT 4.0 or Xp, with a free RS-232 port (COM1 or COM2) to perform the software installation;
PM9080 optically isolated serial interface cable (as included with the ScopeMeter 190CS model and with the SCC-190 kit) for data interconnection between the PC's RS-232 port and the instrument.
Firmware Level Check - Press USER and F3 [VERSION & CAL …] on your ScopeMeter to check its firmware version.
ScopeMeter® 190C Series Version 6 Firmware Upgrade
A firmware upgrade for ScopeMeter test tool 190C Series is available, major changes are:
- 2mV sensitivity
- pass/fail testing with reference waveform
- dots only display
- user editable setup text
Upgrading Version 5.03 or V5.04 to Version 6.11 - Instruments with version 5.03 , Version 5.04 and version 6.01 are field upgradable free of charge. Click here to download the FlashTool software (750 KB) that allows you to upgrade the instrument firmware.
FlashTool Software requirements:
- Fluke 190C Series Color ScopeMeter, with software V5.03 or V5.04. (See Firmware Level Check above);
- A PC, running Windows 95, 98, Me, 2000, NT 4.0 or Xp, with a free RS-232 port (COM1 or COM2) to perform the software installation;
PM9080 optically isolated serial interface cable (as included with the ScopeMeter 190CS model and with the SCC-190 kit) for data interconnection between the PC's RS-232 port and the instrument
Upgrading earlier Versions - Instruments with firmware version 5.01 and 5.02 cannot be upgraded in the field. These instruments require re-calibration after upgrading. Therefore these units must be returned to a Fluke Authorized Service Center. Contact your local service center and order a firmware upgrade and calibration according to PCN 4841. Note: For the firmware upgrade and calibration a nominal fee will be charged!
ScopeMeter® 123 Version 1 Firmware Upgrade
A firmware upgrade for ScopeMeter test tool 123 is available, major changes are:
- improved battery charge process
- additional probe settings
- supports multiple paper formats for direct printing
Upgrading Version 1.0x to Version 1.08 - Instruments with version 1.0x are field upgradable free of charge. Download the FlashTool software (452 KB) that allows you to upgrade the instrument firmware.
FlashTool Software requirements:
- Fluke 123 Series ScopeMeter, with software V1.0x (See Firmware Level Check below)
- A PC, running Windows 95, 98, Me, 2000, NT 4.0 or Xp, with a free RS-232 port (COM1 or COM2) to perform the software installation PM9080 optically isolated serial interface cable (as included with the ScopeMeter 123S model and with the SCC-120 kit) for data interconnection between the PC's RS-232 port and the instrument
Firmware Level Check - Press USER OPTIONS and F3 [VERSION & CAL …] on your ScopeMeter to check its firmware version. |